Tranny problem Error CEL code P0748 P0758

Thread Tools
 
Rate Thread
 
Old Mar 21, 2009 | 06:19 AM
  #1  
fd3s777's Avatar
Thread Starter
www.EVO-R.Net
iTrader: (2)
 
Joined: Jun 2004
Posts: 852
Likes: 0
From: New York
Unhappy Tranny problem Error CEL code P0748 P0758

Anyone had this problem? I have a 4AT. Under low speed sometime when the car try to shift gear from one to another the tranny locks up and car can only roll at 1-3 MPH and if too fast it lock up again. Its very dangerous cuz car behind me could of ran right into me. When this happen the AT warning light and skid warning light comes up. If I shift to manual shift numbers gear don't light up. I'm getting CEL code:
P0748 Pressure control solenoid
P0758 Shift solenoid B
P0846 Transmisson Fluid Pressure Sensor/ Switch

I check the service manual Pressure control solenoid and shift solenoid B they are under the tranny fix plate.

I want to make sure before I change these solenoids. Anyone ever had this problem? Will change ATF fix the problem? I did try reset the PCM. It helped. But after I shut off the car and ran it again, it did the same. ANy suggestion would be greatly appreciated.
Reply
Old Mar 22, 2009 | 09:02 AM
  #2  
fd3s777's Avatar
Thread Starter
www.EVO-R.Net
iTrader: (2)
 
Joined: Jun 2004
Posts: 852
Likes: 0
From: New York
Help?
Reply
Old Mar 22, 2009 | 11:53 AM
  #3  
EDZRIDE's Avatar
2005 White GT
iTrader: (1)
 
Joined: Feb 2006
Posts: 1,210
Likes: 2
From: Spokane Valley, Washington
Flushing the transmission wouldn't hurt anything but I would run some pressure checks before replacing anything.
Reply
Old Mar 26, 2009 | 11:29 AM
  #4  
fd3s777's Avatar
Thread Starter
www.EVO-R.Net
iTrader: (2)
 
Joined: Jun 2004
Posts: 852
Likes: 0
From: New York
okay. I took out the tranny plate and made a big mess. Tranny oil all over the place and myself. There were alot of metal shred on the tranny bottom plate. I took the tranny filter out and there were even more. Damm this turbo kit is really killing the tranny. Test the ohm of Pressure control solenoid and Shift solenoid B . They were all fine. Clean out all the metal shred and put everything back. Put in new tranny oil. Took out for a spin. Car is all good now. Thanks all.
Reply
Old Mar 26, 2009 | 12:34 PM
  #5  
teknics's Avatar
Certified Mazda Tech
 
Joined: May 2003
Posts: 645
Likes: 12
From: Wayne, NJ
new clean fluid in a trans that had metal shavings everywhere = blown trans.

Seriously i'd start looking into rebuilds or replacements. Most likely the codes were caused by clogged areas caused by the loose metal shavings.

also any time an AT is experiencing shifting problems you DONT want to do a trans flush. Trans flush is a PREVENTATIVE solution, not a repair. In most cases it makes things a lot worse, same thing with if you have never done a trans flush and then do one at 100k.

kevin.
Reply
Old Jun 27, 2016 | 02:38 PM
  #6  
FunRun8's Avatar
Registered
iTrader: (5)
 
Joined: Apr 2013
Posts: 204
Likes: 3
From: Sebring
Ok so sorry to revive an old thread but it'd be nice if this was updated some years later to see how long his remedy lasted? Any chance of that?

Sounds very much like my current issues and I just got a P0758 code this morning I had not gotten previously which is how I found this thread to go along with my other issues with the steering. I also got apparently bogus information from the auto parts store and they said to use Dexron VI when I found a Mazda bulletin that said it should be Dexron III instead so I'm just a bit miffed about that since it is nearly impossible to flush all of the fluid effectively without a massive PITA. How much effect do you suppose that can be having on my issues it's only been in there for a very short period of time and what do you think are the chances it's now damaged my transmission permanently?
Regards in advance.
Reply
Old Jun 28, 2016 | 01:21 PM
  #7  
FunRun8's Avatar
Registered
iTrader: (5)
 
Joined: Apr 2013
Posts: 204
Likes: 3
From: Sebring
Good stuff? So anybody?
Reply
Old May 17, 2022 | 07:51 PM
  #8  
Theofanis's Avatar
New Member
 
Joined: May 2022
Posts: 2
Likes: 0
P0751

Originally Posted by fd3s777
okay. I took out the tranny plate and made a big mess. Tranny oil all over the place and myself. There were alot of metal shred on the tranny bottom plate. I took the tranny filter out and there were even more. Damm this turbo kit is really killing the tranny. Test the ohm of Pressure control solenoid and Shift solenoid B . They were all fine. Clean out all the metal shred and put everything back. Put in new tranny oil. Took out for a spin. Car is all good now. Thanks all.
How did you identify the Solenoid B? I need to identify Solenoid A
Reply
Old May 17, 2022 | 07:54 PM
  #9  
Theofanis's Avatar
New Member
 
Joined: May 2022
Posts: 2
Likes: 0
P0751

Originally Posted by fd3s777
okay. I took out the tranny plate and made a big mess. Tranny oil all over the place and myself. There were alot of metal shred on the tranny bottom plate. I took the tranny filter out and there were even more. Damm this turbo kit is really killing the tranny. Test the ohm of Pressure control solenoid and Shift solenoid B . They were all fine. Clean out all the metal shred and put everything back. Put in new tranny oil. Took out for a spin. Car is all good now. Thanks all.
How did you identify the Solenoid B? I need to identify Solenoid A
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
xAgyex
Series I Trouble Shooting
24
Jul 26, 2025 01:15 PM
Dokuji
Series I Trouble Shooting
8
Nov 1, 2016 02:51 PM
Rx808BI
New Member Forum
4
Aug 9, 2015 10:06 AM
Nisaja
New Member Forum
2
Aug 6, 2015 01:27 AM
SIllver
New Member Forum
0
Aug 1, 2015 07:34 PM



You have already rated this thread Rating: Thread Rating: 0 votes,  average.


All times are GMT -5. The time now is 02:19 PM.