Notices

where to run power wire

Old Apr 12, 2006 | 05:30 PM
  #1  
gotrotary's Avatar
Thread Starter
Registered User
 
Joined: Mar 2006
Posts: 68
Likes: 0
Lightbulb where to run power wire

Hey i was just wondering how people got threw the firewall to the battery on there rx-8's for the power wire. Running 4gauge and was just wondering if you need to drill or if there's a grommet of some sort or something else. I used to be a car audio installer but im to lazy to look myself and figured someone may know. Thanks for the help!!!!
Reply
Old Apr 12, 2006 | 05:49 PM
  #2  
StealthTL's Avatar
Metatron
iTrader: (1)
 
Joined: Mar 2003
Posts: 7,286
Likes: 184
From: A Pacific Island.
Wink Heater....

Go thru the rubber the heater hoses occupy, between the washer bottle and the intake manifold. Might be tight for a 4 gauge, but will fit.

(...and yes, for an installer, that IS pretty lazy! )

S
Reply
Old Apr 12, 2006 | 05:58 PM
  #3  
gotrotary's Avatar
Thread Starter
Registered User
 
Joined: Mar 2006
Posts: 68
Likes: 0
thank you very much i went out and looked after i posted lol. but i just wanted to see other opinions. Thats why im not an Installer Any more, im a lazy car salesmen!
Reply
Old Apr 12, 2006 | 06:33 PM
  #4  
AdamK's Avatar
Registered User
 
Joined: Dec 2005
Posts: 120
Likes: 0
From: Bellevue, WA
Or, you could do this:

http://koczarski.com/RX8/Mods/HAM/HAM.htm
Reply
Old Apr 13, 2006 | 12:47 PM
  #5  
forbidden's Avatar
Registered User
 
Joined: Apr 2005
Posts: 544
Likes: 0
From: CFB Comox, BC, Canada
Or you can run up to two 0 guage lines through the firewall when you remove the windshield washer resevoir. This is where the JDM version of this cars steering wheel would normally go through the firewall, lots of room there.
Reply
Old Apr 13, 2006 | 02:39 PM
  #6  
gotrotary's Avatar
Thread Starter
Registered User
 
Joined: Mar 2006
Posts: 68
Likes: 0
nice that seems to be the right spot and the easiest espically with where the battery is thanks for all the awesome help!
Reply
Old Jun 23, 2007 | 05:10 PM
  #7  
JMaN06's Avatar
Registered User
 
Joined: Jun 2007
Posts: 10
Likes: 0
when i remove the windsheild washer resivour i dont see any holes behind there? do i have to make the hole? of am i just missing it? after i remove the 2 bolts at the top, am i supposed to pull the whole thing out or will it just be there?
Reply
Old Jun 26, 2007 | 07:55 PM
  #8  
jstkilntim's Avatar
resU deretsigeR
 
Joined: Jan 2006
Posts: 743
Likes: 0
From: Jacksonville, FL
Pull the whole thing out. You will have to drill the hole yourself. Do not drill too deep.
Reply
Old Jul 29, 2007 | 01:43 AM
  #9  
u1cracka's Avatar
Registered User
 
Joined: Jun 2006
Posts: 101
Likes: 0
Originally Posted by jstkilntim
Pull the whole thing out. You will have to drill the hole yourself. Do not drill too deep.
How deep can you drill with out hitting anything like wire's
would using a Step up drill bit work good.
Has anyone used a bi-metal hole saw drill bit.


Thanks
U1cracka
Reply
Old Jul 29, 2007 | 07:22 PM
  #10  
jstkilntim's Avatar
resU deretsigeR
 
Joined: Jan 2006
Posts: 743
Likes: 0
From: Jacksonville, FL
To be honest, I measured, but forgot the depth. I used a Blue-Point hole cutter, but I think you should be fine w/ a uni-bit. Just drill the first hole and measure before you go bigger. If the uni-bit is too deep, which I don't think it is, you can always dremmel the hole. It seems like there is insullation behind there too.

Last edited by jstkilntim; Jul 29, 2007 at 07:24 PM.
Reply
Old Jul 29, 2007 | 11:41 PM
  #11  
u1cracka's Avatar
Registered User
 
Joined: Jun 2006
Posts: 101
Likes: 0
Originally Posted by jstkilntim
To be honest, I measured, but forgot the depth. I used a Blue-Point hole cutter, but I think you should be fine w/ a uni-bit. Just drill the first hole and measure before you go bigger. If the uni-bit is too deep, which I don't think it is, you can always dremmel the hole. It seems like there is insullation behind there too.
Thanks for the reply I just got done installing my 0Gauge power wire.
There was about 3inch's of space. I used a bi-metal drill bit it worked fine was going to buy a step up bit but they wanted $50.00 and I was afraid it would go to deep.


Thanks
U1cracka
Reply
Old Jul 30, 2007 | 08:19 PM
  #12  
Crazy Rx-8 Driver's Avatar
XYELLR8
 
Joined: Nov 2005
Posts: 429
Likes: 0
From: Maple Grove, Minnesota
how far did you drill into the firewall?
Reply
Old Jul 30, 2007 | 09:48 PM
  #13  
jstkilntim's Avatar
resU deretsigeR
 
Joined: Jan 2006
Posts: 743
Likes: 0
From: Jacksonville, FL
All the way through!!! (Sorry, couldn't resist.)
Reply
Old Jul 31, 2007 | 02:51 AM
  #14  
u1cracka's Avatar
Registered User
 
Joined: Jun 2006
Posts: 101
Likes: 0
Originally Posted by Crazy Rx-8 Driver
how far did you drill into the firewall?
The firewall is very thin I drilled a small pilot hole and then i used a 7/8 bi metal drill bit. You don't want to push on the drill much so when you drill true it doesn't ram forward when it go's true the firewall.
I then Used a razor blade to cut true the rubber mat that was behind it.



U1cracka
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Audio Concepts ATL
New Member Forum
21
Sep 26, 2021 01:59 PM
uZu
New Member Forum
13
Dec 30, 2015 12:35 PM
akagc
RX-8's For Sale/Wanted
7
Aug 11, 2015 07:07 PM
CMRine04
New Member Forum
15
Jul 29, 2015 02:07 PM
stickmantijuana
Series I Tech Garage
2
Jul 19, 2015 10:33 AM


Thread Tools
Rate This Thread
Rate This Thread:
You have already rated this thread Rating: Thread Rating: 0 votes,  average.


All times are GMT -5. The time now is 11:21 AM.