Notices
RX-8 Discussion General discussion about the RX-8 that doesn't fit in one of the specialty forums.

heater noise

Thread Tools
 
Search this Thread
 
Rate Thread
 
Old 11-13-2003, 11:29 AM
  #1  
Registered User
Thread Starter
 
rieskame's Avatar
 
Join Date: Nov 2003
Posts: 68
Likes: 0
Received 0 Likes on 0 Posts
Question heater noise

is it normal when you are running just the floor vents for the windshield defroster fans to run very loudly when in setting 3 or 4? I cant tell much difference between just floor and blend. If i irun the heat at just setting 2 it is relitively quiet.

thanks
eric
Old 11-13-2003, 07:46 PM
  #2  
Registered
 
B-Nez's Avatar
 
Join Date: Aug 2002
Location: Navarre, FL
Posts: 994
Likes: 0
Received 0 Likes on 0 Posts
Re: heater noise

Originally posted by rieskame
is it normal when you are running just the floor vents for the windshield defroster fans to run very loudly when in setting 3 or 4? I cant tell much difference between just floor and blend. If i irun the heat at just setting 2 it is relitively quiet.

thanks
eric
you should only be hearing the A/C compressor noises. If it sounds the same as "A/C" then it is normal. If it is worse, then you might want to have it looked at.
Old 11-13-2003, 08:01 PM
  #3  
Registered User
Thread Starter
 
rieskame's Avatar
 
Join Date: Nov 2003
Posts: 68
Likes: 0
Received 0 Likes on 0 Posts
the AC is not on it is only 39 degrees here. It is like the defroster is running when it is not supposed to. Is the floor heat mode loud to anyone else?
Old 11-13-2003, 08:09 PM
  #4  
Registered
 
B-Nez's Avatar
 
Join Date: Aug 2002
Location: Navarre, FL
Posts: 994
Likes: 0
Received 0 Likes on 0 Posts
let me try this again...when you select feet only with the logicon, the a/c turns on. read the manual.
Old 11-13-2003, 08:26 PM
  #5  
Registered User
Thread Starter
 
rieskame's Avatar
 
Join Date: Nov 2003
Posts: 68
Likes: 0
Received 0 Likes on 0 Posts
that seems very strange. why even have a AC light if it is going to come on automaticly anyway? my PT did that but only for defrost mode. how do you turn the AC off then? I dont think that is the noise.
Old 11-14-2003, 08:52 AM
  #6  
Registered
 
Gord96BRG's Avatar
 
Join Date: Jan 2003
Location: Calgary, AB
Posts: 2,845
Likes: 0
Received 1 Like on 1 Post
Re: heater noise

Originally posted by rieskame
is it normal when you are running just the floor vents for the windshield defroster fans to run very loudly when in setting 3 or 4?
There is no separate defroster fan - just one fan for interior ventilation, and ducting to direct it to the windshield, floor, vent, or combinations. The sound will change depending on what outlet(s) you've selected, but again it's just the one fan.

Regards,
Gordon
Old 11-14-2003, 04:33 PM
  #7  
Registered User
Thread Starter
 
rieskame's Avatar
 
Join Date: Nov 2003
Posts: 68
Likes: 0
Received 0 Likes on 0 Posts
does the defroster run while in floor only mode? thatr is my question. I will be taking it to Mazda saturday to look at that paint chip and dont want to look stupid.

thanks
Old 11-14-2003, 05:07 PM
  #8  
Registered
 
Gord96BRG's Avatar
 
Join Date: Jan 2003
Location: Calgary, AB
Posts: 2,845
Likes: 0
Received 1 Like on 1 Post
Originally posted by rieskame
does the defroster run while in floor only mode?
There isn't a separate defroster - you only have one interior heating/ventilation system. From the ONE fan, there are ducts going to the defroster vents, the dash vents, and the floor vents. There are flaps that control the distribution of air - if you set it to defrost only, then doors/flaps in the ducts close off the dash and floor vents. If you set the system to floor only, then the doors close off the defroster and dash vents. Make sense?

Do you mean the air conditioning, as in does the a/c run while in floor only mode?

Regards,
Gordon
Old 01-08-2004, 11:55 AM
  #9  
Registered User
 
Srhodes21's Avatar
 
Join Date: Nov 2003
Location: Bury
Posts: 5
Likes: 0
Received 0 Likes on 0 Posts
I have the same issue as Eric. When I turn my system to floor mode with the fan above the 1 setting, there is a loud sound that comes from the defrost area above the dash. It is not the sound of the AC compressor. It is the sound of air seemingly being blown at high velocity through a small openning. Do the rest of you have quiet fan operation in this mode?
Old 01-08-2004, 01:33 PM
  #10  
The Stickinator
 
93rdcurrent's Avatar
 
Join Date: Nov 2003
Location: Portland, OR.
Posts: 1,328
Likes: 0
Received 0 Likes on 0 Posts
The sound you are hearing should just be the one fan blowing air into the car. Then the ducts tell the air where to go by using the selector on the dash. The air is coming into the car via the vents just above the hood and in front of the windshield by the wipers. You will hear the sound coming from the forced air through that region before it is duct to the floor or where ever. Hope this helps.
Old 01-08-2004, 01:56 PM
  #11  
Registered
 
RX-GR8's Avatar
 
Join Date: Aug 2003
Location: Cherry Hill, NJ
Posts: 3,098
Received 3 Likes on 2 Posts
Originally posted by Srhodes21
I have the same issue as Eric. When I turn my system to floor mode with the fan above the 1 setting, there is a loud sound that comes from the defrost area above the dash. It is not the sound of the AC compressor. It is the sound of air seemingly being blown at high velocity through a small openning. Do the rest of you have quiet fan operation in this mode?
it sounds line i'm in a wind tunnel when it's on 3 or 4.
Old 01-08-2004, 01:56 PM
  #12  
Registered
 
f1michel's Avatar
 
Join Date: Aug 2003
Location: Montreal
Posts: 400
Likes: 0
Received 0 Likes on 0 Posts
The fan is way too noisy on this car, don't get me wrong, i love my car but the fan noise is annoying.
Old 01-08-2004, 09:27 PM
  #13  
Lurking troll
 
Magnesium's Avatar
 
Join Date: Jun 2003
Location: Vancouver, WA
Posts: 330
Likes: 0
Received 0 Likes on 0 Posts
Due to design, it is just loud. Probably my biggest complaint, which isn't much. It is what it is...
Old 01-08-2004, 10:34 PM
  #14  
zoom freaking zoom
 
Wankeler's Avatar
 
Join Date: Aug 2003
Location: Ohio
Posts: 241
Likes: 0
Received 0 Likes on 0 Posts
Originally posted by rieskame
does the defroster run while in floor only mode? thatr is my question. I will be taking it to Mazda saturday to look at that paint chip and dont want to look stupid.

thanks
I think I know what rieskame is talking about. On every other setting (vent only, vent/floor, def/floor and defrost), the air flow seems signifigant, but on floor only mode... especially with the fan on 3 or 4, it seems there is air being blown to the defroster area... I have the same problem. In all other modes/positions... it seems on setting 3 or 4 you get a nice stiff breeze... but in floor only mode... the rush of air coming from the floor vents seems mighty weak and it seems as if soe of the airflow is directed at the windshield.... like a flap is stuck. To keep warm, I usually have the seat heaters going and my airflow set to vent/floor.

Never really paid any attention to this till the temps got into the single digits (F not C). BY the way.... I was planning on putting up my baby for the winter months, but I'm addicted to the seat warmers that my other car doesn't have. :D
Old 02-16-2006, 11:53 PM
  #15  
Sho'Nuff
 
Napboy's Avatar
 
Join Date: Jul 2003
Location: San Diego
Posts: 632
Likes: 0
Received 1 Like on 1 Post
i know this is an old thread, but did anyone ever settle this issue? i just noticed that when my vents are set to floor only, it blows through the dash vents also and it's mighty loud at 3 or 4.
Old 02-17-2006, 12:04 AM
  #16  
May Cause Anal Leakage
 
tiggerlee's Avatar
 
Join Date: Oct 2004
Location: Orlando & Chicago
Posts: 3,191
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by Napboy
i know this is an old thread, but did anyone ever settle this issue? i just noticed that when my vents are set to floor only, it blows through the dash vents also and it's mighty loud at 3 or 4.



Well it got a little chilly here earlier in the week and I used the heater for the first time. It was very loud on the 3-4 range. Much louder than I would have anticipated.
Old 02-17-2006, 12:21 AM
  #17  
Sho'Nuff
 
Napboy's Avatar
 
Join Date: Jul 2003
Location: San Diego
Posts: 632
Likes: 0
Received 1 Like on 1 Post
i guess i just find it weird that when you set the vent to "floor only," it's blowing harder out of the dash.
Old 02-17-2006, 03:53 PM
  #18  
Sho'Nuff
 
Napboy's Avatar
 
Join Date: Jul 2003
Location: San Diego
Posts: 632
Likes: 0
Received 1 Like on 1 Post
bump... anyone else have this problem?
Old 02-18-2006, 09:34 AM
  #19  
Registered User
 
Howwls8's Avatar
 
Join Date: Feb 2006
Location: St. Louis, MO
Posts: 6
Likes: 0
Received 0 Likes on 0 Posts
That was one of the first things I noticed when I used my heater for the first time. I was thinking one of the doors that directed the airflow in the dash was messed up or sticking.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
RevMeHarder
New Member Forum
6
08-16-2023 06:23 PM
Mane
New Member Forum
2
11-20-2015 12:16 PM
nowakm99
Series II Technical and Trouble shooting
1
10-09-2015 07:10 AM
tommy26Germany
Series I Trouble Shooting
11
09-29-2015 10:33 AM
Jb4ker96
Series I Trouble Shooting
0
09-27-2015 10:06 PM



You have already rated this thread Rating: Thread Rating: 0 votes,  average.

Quick Reply: heater noise



All times are GMT -5. The time now is 12:36 PM.