Notices
Series I Tech Garage The place to discuss anything technical about the RX-8 that doesn't fit into any of the categories below.

Quantitative Coolant Flow Simulation

Old 09-10-2014, 10:42 AM
  #1  
Scrappy
Thread Starter
iTrader: (1)
 
Legot's Avatar
 
Join Date: Jun 2014
Location: Arizona
Posts: 1,193
Received 7 Likes on 6 Posts
Quantitative Coolant Flow Simulation

*Update! Results of several weeks of CFD are available here! https://www.rx8club.com/series-i-tec...7/#post4631740

Hello all! I just started a little side project of modeling the stock water pump of the RX8, and I need the measurements of the inlet and outlet of the water pump. This is in an effort to help us figure out a high quality estimate the actual flow of the stock system, and to find out exactly where cavitation begins. To do that, I need a moderately accurate model of the inlet and outlet to the pump.

Here's someone elses picture of the coolant passages:



All that I need are five measurements, they are:

Width of the exit passage (on the right)
Length from the bump (separating the exit passage from the round part) to the gasket
Diameter of the inlet passage (circle on the left)
Length from the outer edge of the wear ring (big circle on the left) to the gasket

If anyone has a dry Renesis (either series) or is changing out their water pump/has it out, these measurements would really be helpful. It's ok if they're a millimeter or so off it won't make an appreciable difference.
Attached Thumbnails Quantitative Coolant Flow Simulation-p1010885.jpg  

Last edited by Legot; 09-29-2014 at 03:10 AM.
Old 09-10-2014, 06:19 PM
  #2  
Registered
 
poacherinthezoo's Avatar
 
Join Date: Jan 2013
Location: Ohio
Posts: 356
Likes: 0
Received 0 Likes on 0 Posts
While this will likely be of little, if any, utility for your purposes, I gave it the old college try.

The measurements are corrected for the angle of the image.


Wow, thoroughly boned this up - I forgot that after measure #2, the units change from pixels to mm's since I set the scaling at that time. So my spread sheet is all outta wack (what I have listed as length in pixels is for measurements 3-12 actually in mm's).
Attached Thumbnails Quantitative Coolant Flow Simulation-screen3.jpg   Quantitative Coolant Flow Simulation-screen1.jpg  

Last edited by poacherinthezoo; 09-10-2014 at 10:19 PM.
Old 09-10-2014, 09:22 PM
  #3  
SARX Legend
iTrader: (46)
 
9krpmrx8's Avatar
 
Join Date: Jan 2007
Location: San Antonio, Texas
Posts: 33,784
Received 452 Likes on 366 Posts
Front




Back


Old 09-10-2014, 09:23 PM
  #4  
SARX Legend
iTrader: (46)
 
9krpmrx8's Avatar
 
Join Date: Jan 2007
Location: San Antonio, Texas
Posts: 33,784
Received 452 Likes on 366 Posts
Kind of odd to measure but if you need a different angle let me know.
Old 09-11-2014, 12:04 AM
  #5  
Scrappy
Thread Starter
iTrader: (1)
 
Legot's Avatar
 
Join Date: Jun 2014
Location: Arizona
Posts: 1,193
Received 7 Likes on 6 Posts
Thanks for the attempt poach! I thought about doing the same thing, but decided it would be easier and more accurate to ask here, just in case, lol.

And thank you 9k! It's so awesome that you were willing to do this for me! I'll be sure to publish what I find, know that it might take a while because my computer is slow, and CFD takes much longer than you might think.

For those who might not understand what I'm doing, I'm modeling the flow coolant through the water pump and the impeller in a 3D modeling software (Autodesk Inventor). Once the flow is modeled it can be married to the model of the impeller. This combined model can then be imported directly into a computational fluid dynamics program (Autodesk Simulation CFD). The CFD program can spin the impeller and calculate it's effect on the coolant at any rpm, pressure, point along the blade, or point the impeller. This is actually really CPU intensive (not GPU), so it takes a looooooong time.

With the data from the simulation, we'll be able to see the exact point and condition where cavitation starts (it can direct export a nifty gif-like animation), along with some lovely graphs and stuff.

If anyone wants the same done for, say, the Re-medy water pump, send me a PM with as many accurate measurements of the impeller that you can get. It might not be responsible to post the exact dimensions of an easily machinable part on the internet... It would be a nice comparison to see exactly what their pump improves on, and how much.
Old 09-11-2014, 08:51 PM
  #6  
Out of NYC
iTrader: (1)
 
nycgps's Avatar
 
Join Date: Jun 2005
Location: Planet Earth
Posts: 19,881
Received 31 Likes on 29 Posts
cavitation starts around 6000 ish rpm, it's well documented by Mazda.

Mazmart already did that years ago and you can get that pump from them right now.

on stock pump, constant 9K rpm will overheat your engine. after the swap to Mazmart part its no longer the issue.

Last edited by nycgps; 09-11-2014 at 08:55 PM.
Old 09-11-2014, 09:38 PM
  #7  
Scrappy
Thread Starter
iTrader: (1)
 
Legot's Avatar
 
Join Date: Jun 2014
Location: Arizona
Posts: 1,193
Received 7 Likes on 6 Posts
Originally Posted by nycgps
cavitation starts around 6000 ish rpm, it's well documented by Mazda.

Mazmart already did that years ago and you can get that pump from them right now.

on stock pump, constant 9K rpm will overheat your engine. after the swap to Mazmart part its no longer the issue.
That's ok, I'm doing this to get quantitative data about how well the stock pump works. The program I'm using can output efficiency curves, power use (not counting the loss from bearings), and actual flow rate. I know the mazmart pump is better, but I want to know exactly what the stock pump fails in.

Personally I'm interested in the flow rate and efficiency, but anything that I find out is going to be put out there for the good of the people.
Old 09-12-2014, 07:30 PM
  #8  
Scrappy
Thread Starter
iTrader: (1)
 
Legot's Avatar
 
Join Date: Jun 2014
Location: Arizona
Posts: 1,193
Received 7 Likes on 6 Posts
If anyone is curious as to what CFD looks like (I'm assuming most people haven't done it) this is a screenshot. In this view you can't really tell, but it is being modeled in 3space through the entire water pump.



I'm currently running a test model now, just 1000 steps. It should run the pump up to just 0.5 RPM. I'm just using this to make sure everything is working right before I let it take up a computer for several days running it from 0 to 15000 RPM. As you can see, the impeller placement is off by about 1mm, so that will get fixed before the big model.
Attached Thumbnails Quantitative Coolant Flow Simulation-untitled.jpg  
Old 09-12-2014, 07:34 PM
  #9  
BECAUSE RACECAR
iTrader: (10)
 
Arca_ex's Avatar
 
Join Date: May 2011
Location: Arizona
Posts: 1,413
Likes: 0
Received 8 Likes on 8 Posts
This is pretty cool. I'm very interested in what the flow is in terms of gallons per minute. I'm switching to a remote external pump and that info will make selecting the appropriate pump much easier.
Old 09-12-2014, 10:58 PM
  #10  
Driving my unreliable rx8
 
logalinipoo's Avatar
 
Join Date: Oct 2012
Location: Alvarado, Tx
Posts: 2,051
Received 5 Likes on 5 Posts
Thats pretty cool. I look forward to the results
Old 09-12-2014, 11:02 PM
  #11  
SARX Legend
iTrader: (46)
 
9krpmrx8's Avatar
 
Join Date: Jan 2007
Location: San Antonio, Texas
Posts: 33,784
Received 452 Likes on 366 Posts
I am curious if Mazmart ever did this type of thing. I kind of doubt they did but it's possible. Honestly I never noticed a difference with my Mazmart pump over the stock pump (updated latest version) so I was never convinced it was worth it.

I have a mazmart pump here, would you like any measurements?

Last edited by 9krpmrx8; 09-12-2014 at 11:09 PM.
Old 09-13-2014, 01:10 AM
  #12  
Scrappy
Thread Starter
iTrader: (1)
 
Legot's Avatar
 
Join Date: Jun 2014
Location: Arizona
Posts: 1,193
Received 7 Likes on 6 Posts
Sure, that would be awesome! I doubt that it really increases flow, but it is presumably much better than stock from a cavitation standpoint. If mazmart has quantitative analysis they either would have used it as promotional material, or kept to themselves if wasn't too impressive. It will good to have data available.
Old 09-14-2014, 01:59 PM
  #13  
SARX Legend
iTrader: (46)
 
9krpmrx8's Avatar
 
Join Date: Jan 2007
Location: San Antonio, Texas
Posts: 33,784
Received 452 Likes on 366 Posts
Okay, not sure if I got everything you need so let me know if I missed anything. Sorry for the crappy pics, I had no one to hold stuff so all I got was shaky cell phone pics, lol.



Even with the top of the center of the impeller.


Close up of mazmart impeller.











Last edited by 9krpmrx8; 09-14-2014 at 02:03 PM.
Old 09-14-2014, 03:17 PM
  #14  
Moder8
iTrader: (1)
 
04Green's Avatar
 
Join Date: Aug 2009
Location: Oviedo, Florida
Posts: 2,578
Received 49 Likes on 31 Posts
Cool.

I have that same micrometer, the same missing little door and that same table.

My pump is on back order though..

; )
Old 09-15-2014, 01:24 AM
  #15  
Scrappy
Thread Starter
iTrader: (1)
 
Legot's Avatar
 
Join Date: Jun 2014
Location: Arizona
Posts: 1,193
Received 7 Likes on 6 Posts
Oddly enough, I have the same... ehem *calipers* and table as well. I still have my battery hatch though.

Thanks again 9k!

Finally started CFD on the Stock pump, and the Mazmart impeller is modeled to the best of my ability (anyone with a CNC mill want the part file ?) The stock results from to 15k rpm should be done by tomorrow afternoon (almost 17 hours to calculate everything), but who knows how long it will take to get it to output inlet and outlet velocities correctly.

Once that's done, the mazmart pump is ready to go!

Last edited by Legot; 09-15-2014 at 01:33 AM.
Old 09-15-2014, 02:28 AM
  #16  
BECAUSE RACECAR
iTrader: (10)
 
Arca_ex's Avatar
 
Join Date: May 2011
Location: Arizona
Posts: 1,413
Likes: 0
Received 8 Likes on 8 Posts
Looking forward to the results. Maximum flow rate in GPM before cavitation is what I'm dying to find out.
Old 09-18-2014, 06:00 PM
  #17  
Scrappy
Thread Starter
iTrader: (1)
 
Legot's Avatar
 
Join Date: Jun 2014
Location: Arizona
Posts: 1,193
Received 7 Likes on 6 Posts
So I had to restart it a couple of times and for a while I had the impeller spinning backwards but as it stands we're at step #4040 out of 4500 steps, it looks like cavitation started at ~7200rpm (at ~10k now) and flow is currently ~180L/min.

Does anyone know the pulley ratios? The rpms that I'm using aren't engine rpms, they're impeller rpms.

I should be back with useable numbers in 3 hours or so.

Last edited by Legot; 09-18-2014 at 06:05 PM.
Old 09-29-2014, 03:05 AM
  #18  
Scrappy
Thread Starter
iTrader: (1)
 
Legot's Avatar
 
Join Date: Jun 2014
Location: Arizona
Posts: 1,193
Received 7 Likes on 6 Posts
Results

Evening fellow rotary enthusiasts!

As a recap, this data has been gathered in an effort to model, simulate, and compare the differences in flow between the stock Rx8 water pump and the Remedy Water pump sold by Mazmart! The software used to model the flow through the housing and the impeller was Autodesk Inventor Professional 2015. The computational fluid dynamics package used to simulate the transient flow was Autodesk Simulation CFD 2015.

Each simulation was done under a specific pair of boundary conditions being: 88kPa static pressure (the pressure allowed by a functioning radiator cap), and a temperature of 84.44 degrees Celsius (the target coolant temperature of the stock thermostat). The fluid flow was made of a simulated material that is (in all measurable properties distilled water in order to create a standard. Cavitation is less likely in the majority of coolants due to their higher viscosities.

Cavitation data is not directly available from the simulation, however the amount of cavitation is represented by the combined rate and magnitude of the oscillations in rotating power. This is due to vapor bubble regions forming (water molecules being ripped apart from one another, using a significant amount of power), and the same bubble regions imploding (rapidly decreasing the volume in front of the proceeding blade, sucking it forward with great force).

Here is a brief analysis of some of the results, there is more data available but this is all that is in a presentable/understandable format right now. Oddly, I'm not allowed to upload Excel documents on this forum, so if you really want the summary data then shoot me a pm and I can email it to you.

First up is Power vs Engine RPM!


As you can see from the graph of the stock impeller (blue), there are two main points where cavitation begins, that is at 7735 RPM and 9300 RPM. From 7700 RPM to 9300 RPM there is a serious drop in the transmission of power from the impeller to the flow, suggesting a primary cavitation. A secondary, much more violent cavitation occurs at 9300 RPM and freaking skyrockets from there. Note that the average power would be linearly increasing after 9300 RPM

The graph of the Mazmart impeller shows a significantly lower power usage, and a much more controlled cavitation event.



Next is Flowrate vs Engine RPM (the one everyone cares about)


The data for this portion was tricky, and excel refused to interpolate or make a best fit curve, but this is it. The outlying point at 11700 Engine RPM is some sort of significant change in the vapor bubble region, but should be ignored when analyzing flow.

At 9300 RPM (stock redline), the Stock Impeller is capable of flowing 490 l/min (130 G/min).
At 9300 RPM, the Mazmart Impeller is capable of flowing 345 l/min (91 G/min).



These last two should really be transposed, but excel was giving me issues so I just let it be.

Stock Flow Rate vs Power


Mazmart Flow Rate vs Power


As we've already seen, the Mazmart impeller has a much more consistent power usage, along with significantly less power consumption. For both impellers as flow increases power usage increases exponentially (as expected).


Animation of the cavitation volume fraction of the Stock Pump

Mazmart Pump

The stock redline of 9300 Engine RPM occurs around step 225/300 (shown in the bottom left corner). Each step in the animation is ~150 RPM increase at the impeller or a ~125 RPM increase at the ES.



Now for some provocative facts and notes.

These two simulations were run as accurately as possible, however they are aimed at the max capabilities of the pump itself. It would be very nearly impossible to determine the exact flow rate through the entire coolant system (well, it's possible, but it would take months of simulations). Fortunately coolant systems are designed to flow as much as reasonably possible, which means that the flow data is likely within a +15% margin of error.

The Mazmart impeller flows less than the stock impeller under all conditions. However the efficiency of the stock impeller is less beyond 11000 RPM.

The Stock impeller cavitates more than the mazmart impeller from 7300 RPM onwards.

The curves along the blades on the mazmart impeller are quote simply eccentric circles, offset 60 degrees, the same diameter as the impeller (suggesting that someone with literally no impeller design knowledge made it).

The full disk type lower disk of the mazmart impeller is designed in such a way that the pressure differential on either side will decrease bearing life (not significantly, just a note on poor design choices)

The smoothed edges and gentle of the mazmart impeller are a major contributing factor to it's great cavitation performance at higher RPMs.

Above 11000 RPM, the cavitation of the stock pump would likely cause visible damage to the water pump housing/bearings over time.
Attached Thumbnails Quantitative Coolant Flow Simulation-stock-flowrate-vs-power.png   Quantitative Coolant Flow Simulation-mazmart-flowrate-vs-power.png   Quantitative Coolant Flow Simulation-power-vs-engine-rpm.png   Quantitative Coolant Flow Simulation-flow-rate-vs-engine-rpm.png  

Last edited by Legot; 10-14-2014 at 09:45 PM.
Old 09-29-2014, 03:08 AM
  #19  
Scrappy
Thread Starter
iTrader: (1)
 
Legot's Avatar
 
Join Date: Jun 2014
Location: Arizona
Posts: 1,193
Received 7 Likes on 6 Posts
Can someone change the title of this thread to something like "Quantitative Coolant Flow Simulation" please?

Now, everyone feel free to discuss opinions. IMO, it is a total waste and kind of a modest step backwards to "upgrade" to the Mazmart impeller.

Last edited by Legot; 09-29-2014 at 03:11 AM.
Old 09-29-2014, 03:22 AM
  #20  
BECAUSE RACECAR
iTrader: (10)
 
Arca_ex's Avatar
 
Join Date: May 2011
Location: Arizona
Posts: 1,413
Likes: 0
Received 8 Likes on 8 Posts
Wow those are some pretty interesting results. Good stuff.

I guess the next interesting thing to know would be what volume of flow is most effective for removing heat.

Also pretty cool to finally know how much horsepower the water pump consumes. Almost 7BHP at redline is more than I thought it would be.
Old 09-29-2014, 05:04 AM
  #21  
Metatron
iTrader: (1)
 
StealthTL's Avatar
 
Join Date: Mar 2003
Location: A Pacific Island.
Posts: 7,280
Received 172 Likes on 130 Posts


Am I the only one who's this immature?
Old 09-29-2014, 05:33 AM
  #22  
You gonna eat that?
iTrader: (1)
 
BigCajun's Avatar
 
Join Date: Jan 2013
Location: Kansas City, Mo.
Posts: 5,989
Received 2,591 Likes on 2,111 Posts
I need more graphs.
Old 09-29-2014, 07:40 AM
  #23  
Driving my unreliable rx8
 
logalinipoo's Avatar
 
Join Date: Oct 2012
Location: Alvarado, Tx
Posts: 2,051
Received 5 Likes on 5 Posts
I see it stealth, but not before you said something.
Old 09-29-2014, 07:54 AM
  #24  
Driving my unreliable rx8
 
logalinipoo's Avatar
 
Join Date: Oct 2012
Location: Alvarado, Tx
Posts: 2,051
Received 5 Likes on 5 Posts
Thanks very much legot.

Arca, I think best cooling is subjective to total system flow and the radiator you have.

I would be really interested in seeing how much is flowing through the throttle body and heater core. To know how much you are just recirculating and getting hotter. Also how much flows through the thermostat bypass hole.

Maybe a thermostat model to see how much it could flow. I bet that is a significant restriction.
Old 09-29-2014, 09:08 AM
  #25  
SARX Legend
iTrader: (46)
 
9krpmrx8's Avatar
 
Join Date: Jan 2007
Location: San Antonio, Texas
Posts: 33,784
Received 452 Likes on 366 Posts
Good stuff.

Thread Tools
Search this Thread
Rate This Thread
Rate This Thread:
You have already rated this thread Rating: Thread Rating: 0 votes,  average.

Quick Reply: Quantitative Coolant Flow Simulation



All times are GMT -5. The time now is 12:26 AM.